Part Number Hot Search : 
EVH12390 13007 P2288 SEL2910D CY14B SF1605G ACE4000 DT430
Product Description
Full Text Search
 

To Download LX350 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 LX350 SERIES
Flexible single and multiple outputs
* * * * * * * 350W continuous, 550W peak output power Industry standard footprint, low profile Conducted noise to meet EN55022 class B AC and DC input voltage options in same package Efficiency up to 88% Optional power sharing/VME signals Autoranging input
[ 2 YEAR WARRANTY ]
The LX350 series offers 350 Watts of continuous output power in a low profile industry standard footprint. With two standard single output options and a flexible standard multiple output version, the series can address most requirements as standard. The design is specifically tailored to allow full flexibility and modifications to meet customer applications can be implemented with relative ease. The LX350 AC input series meets the safety requirements of EN60950, VDE0805, UL1950 and CSA 22.2 No. 950. Input conducted noise levels meet the requirements of EN55022 class B. LX350 series power supplies are ideal for use in applications such as point-of-sale equipment, central and public telecom power systems and network equipment.
SPECIFICATION
OUTPUT SPECIFICATIONS Voltage adjustability Remote sense Line regulation (LL to HL, FL) Load regulation (20% to 100% FL)
All specifications are typical at nominal input, full load at 25C unless otherwise stated ELECTROMAGNETIC COMPATIBILITY SPECIFICATIONS -8%/+16% 20% 10% Conducted emissions Radiated emissions ESD air ESD contact Surge Fast transients Radiated immunity Conducted immunity EN55022, level B EN55022 EN61000-4-2, level EN61000-4-2, level EN61000-4-5, level EN61000-4-4, level EN61000-4-3, level EN61000-4-6, level
Vout on singles +5V output on multiple
Single outputs Multiple: +5V output Multiple: aux. outputs, Note 4 Singles Multiple: +5V output Multiple: 12, +24V outputs Multiple: -5V output, Note 4 5A load step on main output Auxiliary outputs, Note 4 25% di/dt
0.2% 0.2% 0.5% 0.2% 1.0% 2.0% 4.0% 1.0%
3 4 3 3 3 3
Perf. Perf. Perf. Perf. Perf. Perf.
criteria criteria criteria criteria criteria criteria
1 1 1 1 2 1
GENERAL SPECIFICATIONS Hold-up time Efficiency 110/230VAC 28ms 82% min. Input/output Input/chassis Fixed 3000VAC 1500VAC 44kHz EN60950, VDE0805, UL1950 CSA C22.2 No. 950 2.5kg (88oz)
Cross regulation Transient response
Isolation voltage Switching frequency Approvals and standards, See Note 7 Weight
1% max. dev. 1ms recovery 0.02%/C 0.04%/C
Temperature coefficient Main/single output Multiple: auxiliary outputs Overvoltage protection Output power limit Main/single output
130% 10% Vout
Multiples: 600W Pout primary power limited Singles: 105%-120% Iout current foldback All outputs Yes
ENVIRONMENTAL SPECIFICATIONS Thermal performance Operating 0C to +70C Non-operating -25C to +85C 0C to 40C ambient, 350W convection cooled 40C to 70C ambient, Derate linearly convection cooled to 25% full load Peak (0C to 40C, max. 10s) 550W Non-condensing Operating Non-operating Operating, 5-50Hz Operating, 50-100Hz Non-operating 5% to 95% RH 10,000 feet max. 30,000 feet max. 0.05mm, pk-pk 0.025mm pk-pk 100mm drop on chassis face
Short circuit protection
INPUT SPECIFICATIONS Input voltage range See Note 5 Input surge current Input frequency Safety ground leakage current Remote OFF 110VAC, 60Hz 230VAC, 50Hz Autorange fitted as standard Drop-out voltage 98 to 132VAC 190 to 264VAC 90VAC 25A, max. 50Hz/60Hz 1.6mA 2.5mA Logic 0 on ROF
Relative humidity Altitude Vibration
PAGE 1
AC/DC POWER SUPPLIES
|
350W AC
350 Watt AC/DC universal input switch mode power supplies
OUTPUT VOLTAGE +5.0V -5.0V -12.0V +12.0V +24.0V 24.0V 48.0V
(3) (3)
OUTPUT CURRENTS MAX
(1)
OUTPUT RIPPLE RMS 0.2% 0.2% 0.2% 0.2% 0.2% 0.1% 0.1% PK-PK 2.0% 2.0% 2.0% 2.0% 2.0% 1.0% 1.0% LX350-7624 LX350-7617 MODEL NUMBER LX350-7620
PEAK
(2)
50.0A 4.0A 4.0A 8.0A 4.0A 16.0A 8.0A
100.0A 10.0A 10.0A 20.0A 10.0A - -
INPUT CONNECTIONS Pin 1 Pin 2 Pin 3 Earth Neutral Live
Notes
1 The multiple output LX350 has a continuous output power rating of 350W. The single-output versions have a continuous output power rating of 385W. Peak power figures for individual outputs on the multiple output unit are for less than 10 seconds duration. The overall peak power for the unit is 550W for 10 seconds duration. Single output models are adjustable -8%, +16%. A 10% load on the main output is necessary to maintain regulation on the auxiliaries at full load (multi output model). The input board is fitted with an autorange circuit as standard which automatically senses the input voltage and switches to the appropriate voltage range. This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. Consideration should be given to measuring the temperature on the main transformer (T1) when the power supply is installed in end-use equipment. The measured temperature on T1 must not exceed 90C. For further information on the LX350 safety approvals, contact Computer Products.
2
3 4
OUTPUT CONNECTIONS MULTI O/P 1 2 3 4 5 6 7 8 9 10 11 12 +5VS +5V +5V +5V 0V 0V 0V -5V -12V +12V +24V ROF SINGLE O/P 0VS 0V 0V 0V 0V 0V +V +V +V +V +VS ROF SIGNALS SRS ACF DCF PM PS ROF +VS 0V - - - -
5
6 7
Options
* * DC input models for 24V and 48V operation are detailed on the LX200, LX350 and LX550 series DC/DC converter data sheet on page 170. A safety cover and signals board are available as options. To order, add the suffixes `-C', `-S' respectively , see table below.
OPTIONS
None Cover Signals Cover and Signals
SUFFIX
-C -S -C-S
EXAMPLE
LX350-76xx LX350-76xx-C LX350-76xx-S LX350-76xx-C-S
OVERLOAD/SHORT CIRCUIT PROTECTION
The overload/short circuit protection mechanisms are different for the single output models and the multiple output model. The single output models will current limit when the output load reaches 105-120% of maximum load during overload or short circuit conditions. The unit will operate in a constant current mode making the single output models suitable for battery charging applications. The multiple output model uses a power limiting function. When the total output power reaches 600W the outputs will foldback to the values detailed below: Foldback Value Output +5V 30A continuous +12V 8A continuous +24V 4A continuous -5V/-12V Protected by 4A Multi FuseTM The outputs will not foldback until the total output power exceeds the maximum power limits. This allows the units to have a peak power capability but it requires that care must be taken not to permanently overload any individual output. The +5V, +12V and +24V outputs are not individually protected and it is recommended that the maximum continuous load does not exceed the value given in the output specifications. The -5V and -12V outputs are individually protected by a 4A Multi FuseTM and the maximum continuous load should not exceed the value given in the output specifications.
SIGNALS (OPTIONAL)
An optional signals board supplies the following VME utility bus signals: ACF (AC Fail) Logic 1 to 0 transition occurs >10ms before outputs fall below 80%-85% of nominal in the event of input failure. DCF (DC Fail) Logic 0 occurs if output falls below <85%-95% of nominal. SRS (System Reset) Logic 1 for system OK (AC and DC good and reset times [200ms]) PM Power Monitor signal, proportional to the output power, ratio of 10mV/W, 10%. PS Power Share connections, to be joined for parallel operation of two or more units, ensuring equal power share. For power share operation unit outputs need to be set to 5% of each other and should be connected in star configurations with the load as star centre.
http://www.artesyn.com
PAGE 2
AC/DC POWER SUPPLIES
|
350W AC
350 Watt AC/DC universal input switch mode power supplies
Mechanical notes
A Input and output connectors are 3 way and 11 way 9.5mm barrier strip with M4 X 8 fixings, 250V 20A. Signals board connector is 8 way, single row right angle 0.1", Molex 910210128, this mates with 90147 1108 or equivalent. B Customer fixing screws (A) are M3 isometric. They must not penetrate into unit by more than 5mm.
INPUT
12 3 45 SYSTEM O. K. LED
SIGNALS
1 12 8
OUTPUT
12 3456 7 8 9 10 11
11.81 (300.00)
A
A
7.48 (190.00)
A
A
1.18 (30)
1.18 (30.00) 0.71 (18.00)
9.44 (240.00)
10.39 (264.00)
2.48 (63.00.00)
A
A
A
A
ALL DIMENSIONS IN INCHES (mm)
DERATING CURVE
Output Power (Watts)
550W PEAK OUTPUT POWER 350W
International Safety Standard Approvals:
Multiple output and 24V Single output units are approved to these standards. Safety approval pending for 48V output model. See Note 7 EN60950/VDE0805 Reg. File No. 90370
NATURAL CONVECTION COOLING 87.5W 0W 0C 10C 20C 30C 40C 50C 60C 70C
UL1950 File No. E136005 CSA C22.2 No. 950 File No. LR41062C/LR101320
PAGE 3
(22.50) (20.00)
0.89
0.79
5.12 (130)
DS_LX350AC_19980401.PDF
Data Sheet (c) Artesyn Technologies(R) 2000 The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
http://www.artesyn.com
PAGE 4


▲Up To Search▲   

 
Price & Availability of LX350

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X